Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V1.15.0.0, V1.16.0.0
-
Fix Version/s: V1.15.0.11 (open), V1.16.0.3 (open), V1.16.3.0
-
Component/s: Device
-
Labels:
-
Account:SPC Profinet Core V1 operational (SPCPROFINET)
Description
The stack may generate unexpected and wrong Check Indications in case of SR-AR especially during dynamic reconfiguration but also during connect and abort situations. The following scenarios are known, other may exists as well:
- Unexpected "UNUSED" check indications during dynamic reconfiguration when submodules which are already configured in the stack are added to the SR-AR
- Check indications are already sent when SR-AR with new configuration connects before this AR becomes primary and the configuration is applied.