Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-859

Unexpected Check Indications for SR-ARs in various situations

    Details

    • Account:
      SPC Profinet Core V1 operational (SPCPROFINET)

      Description

      The stack may generate unexpected and wrong Check Indications in case of SR-AR especially during dynamic reconfiguration but also during connect and abort situations. The following scenarios are known, other may exists as well:

      • Unexpected "UNUSED" check indications during dynamic reconfiguration when submodules which are already configured in the stack are added to the SR-AR
      • Check indications are already sent when SR-AR with new configuration connects before this AR becomes primary and the configuration is applied.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  RAamidi Redouane Aamidi
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: