Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V5.3.0.0, V5.4.0.0
-
Labels:
-
Account:SPC Profinet Slave V5 operational (SPCPROFINE)
Description
In case system Redundancy, when plugging a new submodule the ownership is assigned to first established SR-AR according to the rule "First Come First Served". However, this only applies if there is no primary SR-AR. Otherwise, the primary SR-AR always gets the ownership regardless of when it was established.
Attachments
Issue Links
- is blocked by
-
PSPNCORE-437 [System Redundancy] Unexpected ownership handling while plugging submodules
-
- Closed
-
- is cloned by
-
PSPNSV4-1206 [System Redundancy] Submodule ownership not handled properly
-
- Closed
-
- requested
-
PSPNSV5-282 Upgrade Profinet Core to V1.12.3.0
-
- Closed
-