Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-1206

[System Redundancy] Submodule ownership not handled properly

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case system Redundancy, when plugging a new submodule the ownership is assigned to first established SR-AR according to the rule "First Come First Served". However, this only applies if there is no primary SR-AR. Otherwise, the primary SR-AR always  gets the ownership regardless of when it was established.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    RAamidi Redouane Aamidi
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: