Check Indication service and parallel running acyclic services may corrupt each other in LOM usecase

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.5.0.0, V4.6.0.0, V4.7.0.0
    • Fix Version/s: V4.7.0.4, V4.7.2.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the Profinet Device V4 LOM usecase receives an acyclic service request from network and processes a Check Indication service in parallel, either the acyclic service or the Check Indication service may be corrupted. The problem can most likely be seen when a submodule is plugged at the same time a Read/Write record access occurs. Affected services from this behavior are:

      • Check Indication Service
      • AR Check Service
      • Parameter SpeedUp Service
      • Read Record Service
      • Write Record Service
      • Read I&M Service
      • Write I&M Service

      The problem does not affect LFW usecases.