  2. PSPNDIF-234

Check Indication service and parallel running acyclic services may corrupt each other

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V1.0.0.0, V1.1.0.0, V1.2.0.0, V1.3.0.0, V1.4.0.0, V1.5.0.0
    • Fix Version/s: V1.4.0.3, V1.5.0.2, V1.5.2.0
    • Component/s: GCI Adapter
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the firmware receives an acyclic service request from network and processes a Check Indication service in parallel, either the acyclic service or the Check Indication service may be corrupted. The problem can most likely be seen when a submodule is plugged at the same time a Read/Write record access occurs. Affected services from this behavior are:

      • Check Indication Service
      • AR Check Service
      • Parameter SpeedUp Service
      • Read Record Service
      • Write Record Service
      • Read I&M Service