Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Major
-
Resolution: Fixed
-
Affects Version/s: V1.0.0.0, V1.1.0.0, V1.2.0.0, V1.3.0.0, V1.4.0.0, V1.5.0.0
-
Component/s: GCI Adapter
-
Labels:None
-
Account:SPC Profinet Slave V5 operational (SPCPROFINE)
Description
When the firmware receives an acyclic service request from network and processes a Check Indication service in parallel, either the acyclic service or the Check Indication service may be corrupted. The problem can most likely be seen when a submodule is plugged at the same time a Read/Write record access occurs. Affected services from this behavior are:
- Check Indication Service
- AR Check Service
- Parameter SpeedUp Service
- Read Record Service
- Write Record Service
- Read I&M Service
Attachments
Issue Links
- blocks
-
PSPNSV4-1438 Upgrade Profinet Device Interface to V1.5.2.0
-
- Closed
-
-
PSPNSV4-1452 Upgrade Profinet Device Interface to V1.5.0.2
-
- Closed
-
-
PSPNSV5-512 Upgrade Profinet Device Interface to V1.5.2.0
-
- Closed
-
-
PSPNSV5-528 Upgrade Profinet Device Interface to V1.5.0.2
-
- Closed
-
-
PSPNSV5-529 Upgrade Profinet Device Interface to V1.4.0.3
-
- Closed
-
- requested by
-
PSPNSV5-526 Check Indication service and parallel running acyclic services may corrupt each other
-
- Closed
-
-
PSPNSV4-1451 Check Indication service and parallel running acyclic services may corrupt each other in LOM usecase
-
- Closed
-