In some cases on connection abort not all unused check indications are generated

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.7.0.0, V3.8.0.0, V3.9.0.0, V3.10.0.0, V3.11.0.0, V3.12.0.0, V3.13.0.0
    • Fix Version/s: V3.13.0.3, V3.13.2.0, V3.14.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the application configures the protocol to send "Unused" Check Service indications, it might happen that when the connection is aborted, some expected Check Service indications for unused submodules are not sent. The problem occurs when a new connection is established while the protocol implementation is still sending Check Service indications related to a previous connection abort scenario.

      It is expected that all check indications are generated as defined.