Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V3.12.0.0, V3.13.0.0
-
Component/s: Stack
-
Labels:
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
Non-Profinet devices may report a PortID or ChassisID in their LLDP frame which are valid by terms of LLDP specification but do not match expected coding of Profinet specification.
In such a case the Profinet specification states that in all Profinet record objects the corresponing fields shall be set reported "empty".
Current implementation reports the original values from LLDP which do not match Profinet coding.
Attachments
Issue Links
- relates to
-
PSPNS-2803 Update to LLDP V4.4.0.10
- Closed
-
PSLLDP-133 Sometimes Non-Profinet peer data are not reported to the registered application.
- Closed
-
PSPNS-2886 PDPortRealData record may contain unexpected PeerStationName in case of Non-Profinet neighbor
- Closed