Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1811

feature: add support for automatic IP and NameOfStation handling in case of packet configuration

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.5.41.1
    • Fix Version/s: V3.5.44.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint KW 27 2014, PI Sprint KW 27 2014, PI Sprint KW 29 2014
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Currently a user using PNS_IF_SET_CONFIGURATION_REQ is forced to handle NameofStation and IP parameters in his application.
      He needs to do it in the right way to pass certification.

      A mode shall be added to the stack (activated by a new flag in PNS_IF_SET_CONFIGURATION_REQ ulSystemFlags) so that the Name and IP shall be handled by the stack. It shall be taken from the remanent data and values inside PNS_IF_SET_CONFIGURATION_REQ shall be ignored.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated: