Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V0.0.0.0
-
Component/s: GCI Adapter
-
Labels:
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
When the application configures the GCI interface to pass I&M services to the application and a Read Implicit with Target ARUUID is made on any I&M related record object, an invalid resource handling within the GCI adapter occurs. This blocks the RPC handling of the Profinet Protocol Stack indefinitely.
It is expected that resources are handled properly and no such blocking occurs.
Attachments
Issue Links
- blocks
-
PSPNSV5-222 Upgrade Profinet Device Interface to V1.2.0.3
- Closed
-
PSPNSV5-223 Upgrade Profinet Device Interface to V1.3.0.3
- Closed
- is blocked by
-
PSPNSV5-221 Firmware stuck after Read Implict service with Target AR for I&M records
- Closed
- is cloned by
-
PSPNDIF-120 Invalid resource use on Read Implicit of I&M records
- Closed