Invalid resource use on Read Implicit of I&M records

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V0.0.0.0
    • Fix Version/s: V1.0.0.4
    • Component/s: GCI Adapter
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the application configures the GCI interface to pass I&M services to the application and a Read Implicit with Target ARUUID is made on any I&M related record object, an invalid resource handling within the GCI adapter occurs. This blocks the RPC handling of the Profinet Protocol Stack indefinitely.

      It is expected that resources are handled properly and no such blocking occurs.