Uploaded image for project: 'PROFINET IO-Device V5'
  1. PROFINET IO-Device V5
  2. PSPNSV5-221

Firmware stuck after Read Implict service with Target AR for I&M records

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the firmware receives a Read Implicit service with set Target ARUUID for an I&M related record and the application has configured the firmware to pass all I&M services to the application, the firmware becomes stuck in a state were it won't respond to any RPC services anymore.

      It is expected that the services are handled and the firmware continues operation.

      There is no work-around.

      This issue occurs when executing the ART certification testcase DifferentAccessWays.

      The problem does not occur when the firmware is configured to handle I&M by itself.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: