Profinet Device frame buffer drain when second chassis mode enabled

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.9.0.1, V1.10.0.0
    • Fix Version/s: V1.9.0.9, V1.10.0.1, V1.10.1.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      When the Profinet Device network switch is initialized in dual chassis mode (e.g. NDIS usecase) sending multicast frames on first chasses results in frame buffer loss. After a while no more NRT frame buffers are available and sending is not possible anymore.