Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-1164

Network communication stops operation after a while if NDIS API is activated

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.5.0.0
    • Fix Version/s: V4.5.0.2, V4.5.1.0, V4.6.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The integrated Profinet Network Switch might enter a state where sending and receiving of non NWC and non RTC frames is not working anymore. This affects Profinet Acyclic Services, Profinet Connection Management and for LFW usecase IP Socket API communication and Raw Ethernet interface on Communication Channel 0.

      For the LFW usecase the problem only occurs when enabling the NDIS interface.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: