Get_Attribute_All response of TCP/IP Interface object holds invalid data for Safety Network Number (SNN) attribute in case the SNN is not supported.
The SNN part inside the response should be all zeros. Instead the stack delivers all FFs.
Attachments
Issue Links
- relates to
-
PSEISV3-449 Support of Identity object's reset service (service code 0x05) shall be disabled for CIP Safety Applications
-
- Closed
-
Expenses
Activity
Field | Original Value | New Value |
---|---|---|
Link |
This issue relates to |
Status | New [ 10020 ] | Acknowledged [ 10018 ] |
Fix Version/s | V3.4.4.0 (open) [ 40202 ] |
Status | Acknowledged [ 10018 ] | Confirmed [ 10008 ] |
Status | Confirmed [ 10008 ] | Assigned [ 10019 ] |
Description |
Get_Attribute_All response of TCP/IP Interface object holds invalid data for Safety Network Number (SNN) attribute in case the SNN is not supported. The SNN part inside the response should be all zeros. Instead the stack delivers all FFs.
|
Get_Attribute_All response of TCP/IP Interface object holds invalid data for Safety Network Number (SNN) attribute in case the SNN is not supported. The SNN part inside the response should be all zeros. Instead the stack delivers all FFs.
|
Status | Assigned [ 10019 ] | IN PROGRESS [ 3 ] |
Status | IN PROGRESS [ 3 ] | In Review [ 10022 ] |
Resolution | Fixed [ 1 ] |
Status | In Review [ 10022 ] | Resolved [ 5 ] |
Security | Internal [ 10103 ] |
Status | Resolved [ 5 ] | Closed [ 6 ] |
Fix Version/s | V3.5.0.0_RC1 (open) [ 46000 ] |
Account | SPC EthernetIp Slave (SPCETHERNE) [ 1544 ] |