Uploaded image for project: 'EtherNet/IP Core V2'
  1. EtherNet/IP Core V2
  2. PSEIPCORE-303

[Scanner] Target configuration data is restricted to 400 bytes

    Details

    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      The current implementation of the EIP Core, the size of the application segment #2 is restricted to max values of 400 bytes. Therefore the stack is unable to establish a connection and goes into a block.

      The actual limit shall be 510 bytes, which is the maximum that can be put into a single data segment when being transferred to an IO target in the ForwardOpen request.

      Documentation must be also adapted accordingly (EIP_OBJECT_REGISTER_CONNECTEION_REQ).

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    ynikolov Yordan Nikolov
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: