Description
Several new definitions have been made that result in modifications to be done to the Profinet IO Device firmware. This includes
- Profinet IO Device Protocol stack integrated in firmware shall no longer change the IP configuration if it enters bus state off.
- Firmware shall offer a possibility via taglist to configure if (and after which timeout) the PHYs shall be enabled autonatically.
- Profinet IO Device protocol stack shall assign all COM CPU MAC Addresses once they are valid (in order to allow NDIS API of NetworkService DPM Channel to be used without Protocol stack configuration).
- Firmware shall offer a possibility via taglist to configure which IP ports shall be useable on Socket API of NetworkService DPM Channel without Protocol stack configuration).
Attachments
Issue Links
- blocks
-
PSPNSV5-148 Add new taglist entry to control phy activation timeout
- Closed
-
PSPNSV5-164 Add taglist entry to configure IP ports usable when no ip address assigned
- Closed
-
PSPNSV5-150 Change behavior of bus state changes regarding to IP stack handling
- Closed
- is cloned by
-
PRODPNSV4-233 Adjust implementation to new requirements for NetworkService DPM CommunicationChannel
- Closed