Adjust implementation to new requirements for NetworkService DPM CommunicationChannel

    Details

    • Type: Epic
    • Status: Closed
    • Priority: Minor
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: V4.6.0.0
    • Labels:
    • Epic Name:
      PNSv4 NW Channel
    • Epic Status:
      Done
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Several new definitions have been made that result in modifications to be done to the Profinet IO Device firmware. This includes

      1. Profinet IO Device Protocol stack integrated in firmware shall no longer change the IP configuration if it enters bus state off.
      2. Firmware shall offer a possibility via taglist to configure if (and after which timeout) the PHYs shall be enabled autonatically. By default PHYs stay off until configuration is applied.
      3. Profinet IO Device protocol stack shall assign all DDP MAC Addresses once they are valid (in order to allow NDIS API of NetworkService DPM Channel to be used without Protocol stack configuration). Validity is indicated by DDP state.
      4. Firmware shall offer a possibility via taglist to configure which IP ports shall be useable on Socket API of NetworkService DPM Channel without Protocol stack configuration).