Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V5.0.2.0, V5.1.0.0
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The following services shall no longer be supported by PNSv5. The command shall be rejected with "unknown command".

      • PNS_IF_SET_WARMSTART_PARAM_REQ            = 0x00001F6A
      • PNS_IF_SET_OLD_CONFIGURATION_REQ          = 0x00001FC0
      • PNS_IF_SET_PORT_MAC_REQ                   = 0x00001FE0
        • use system service to modify data provider content instead
      • PNS_IF_SEND_PROCESS_ALARM_REQ             = 0x00001F52
        • use SendUserAlarm service instead
      • PNS_IF_RETURN_OF_SUB_REQ                  = 0x00001F50
        • no longer required, automatically handled
      • PNS_IF_SEND_DIAG_ALARM_REQ                = 0x00001F4C
        • no longer required, automatically handled
      • HIL_SET_FW_PARAMETER_REQ = 0x00002F86

      The following parametertypes in SetOem shall be rejected with "invalid parameter type".

      • PNS_IF_SET_OEM_PARAMETERS_TYPE_1
      • PNS_IF_SET_OEM_PARAMETERS_TYPE_2
      • PNS_IF_SET_OEM_PARAMETERS_TYPE_4
      • PNS_IF_SET_OEM_PARAMETERS_TYPE_9

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: