Description
The following services shall no longer be supported by PNSv5. The command shall be rejected with "unknown command".
- PNS_IF_SET_WARMSTART_PARAM_REQ = 0x00001F6A
- PNS_IF_SET_OLD_CONFIGURATION_REQ = 0x00001FC0
- PNS_IF_SET_PORT_MAC_REQ = 0x00001FE0
- use system service to modify data provider content instead
- PNS_IF_SEND_PROCESS_ALARM_REQ = 0x00001F52
- use SendUserAlarm service instead
- PNS_IF_RETURN_OF_SUB_REQ = 0x00001F50
- no longer required, automatically handled
- PNS_IF_SEND_DIAG_ALARM_REQ = 0x00001F4C
- no longer required, automatically handled
- HIL_SET_FW_PARAMETER_REQ = 0x00002F86
The following parametertypes in SetOem shall be rejected with "invalid parameter type".
- PNS_IF_SET_OEM_PARAMETERS_TYPE_1
- PNS_IF_SET_OEM_PARAMETERS_TYPE_2
- PNS_IF_SET_OEM_PARAMETERS_TYPE_4
- PNS_IF_SET_OEM_PARAMETERS_TYPE_9
Attachments
Issue Links
- clones
-
PSPNSV5-3 drop support for some packet services