Description
The certification testcase "DiffAccessWays" may report errors (invalid IOPS/IOCS value) in the following conditions:
- using a SystemRedundancy enabled firmware
- executing SystemRedundancy related testcases
- afterwards execute testcase "DiffAccessWays"
The testcase "DiffAccessWays" is passed when executed if no SystemRedundancy AR has ever been established. It is expected that the testcase is always passed.
Note: In "normal" usage of certification tool the testcase DiffAccessWays is executed prior any SystemRedundancy AR and thus the issue may not appear in first testrun of the certification test tool.
"Standard" firmware not supporting SystemRedundancy is not affected by this ticket.