Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-821

Wrong CMI/CPM connection monitoring in for legacy startup

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.2.0.0, V4.3.0.0, V4.4.0.0
    • Fix Version/s: V4.4.4.0, V4.5.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When a connection is established in legacy startup mode, an unexpected CMI timeout might be observed. The problem can be observed with a slow application delaying the application ready by more than 60 seconds.

      The CMI monitoring is not stopped and the CPM monitoring is not started when RPC Write or RPC ParamEnd is received as required by Profinet Specification V2.2.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: