wrong byteorder for AM_Location used in AssetManagment record

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.3.1.0
    • Fix Version/s: V4.4.0.1
    • Labels:
      None
    • Sprint:
      PI Sprint 2018 KW 11/12
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Due to a bug in Wireshark and a clarification for the Profinet specification it is now clear that the field "AM_Location" inside the AssetManagment record is filled with wrong byteorder by protocol stack.

      Note that Wireshark up to 2.4.4, 2.2.12 and 2.5.0 have wrong decoding.

      If Wireshark shows a correct AssetManagment dataset field "AM_Location" than the implementation in protocol stack is wrong.