Wrong encoding of AM_Location field inside AssetManagment record object

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.12.0.11, V3.12.2.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2018 KW 11/12
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Due to a clarification of the Profinet specification it is now clear that the field "AM_Location" inside the AssetManagment record is filled with wrong byteorder by protocol stack.

      Note that all Wireshark versions up to 2.5.x have also wrong decoding implemented. Starting with Wireshark 2.6.0 the decoding in Wireshark is correct.