Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V3.12.0.0
-
Fix Version/s: V3.12.0.11, V3.12.2.0, V3.13.0.0
-
Component/s: None
-
Labels:None
-
Sprint:PI Sprint 2018 KW 11/12
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
Due to a clarification of the Profinet specification it is now clear that the field "AM_Location" inside the AssetManagment record is filled with wrong byteorder by protocol stack.
Note that all Wireshark versions up to 2.5.x have also wrong decoding implemented. Starting with Wireshark 2.6.0 the decoding in Wireshark is correct.
Attachments
Issue Links
- relates to
-
PSPNS-2874 Wrong coding of AM_DeviceIdentification in asset management block
- Closed
-
PSPNSV4-816 wrong byteorder for AM_Location used in AssetManagment record