Details
-
Type: Bug
-
Status: Closed
-
Priority: Major
-
Resolution: Fixed
-
Affects Version/s: V4.2.0.0
-
Labels:
-
Sprint:PI Sprint 2016 KW 16/17
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
Executing the PNIO Tester testcase CHECK_PEERS_DIFF leads to different results depending on how the firmware is configured.
All tests are done with netX52 NXLFW on NXHX52-JTAG board.
Scenario 1)
Configuration with Sycon.net database and no application on DPM. All is fine, no error in manual testcase evaluation.
Scenario 2)
Configuration with PNS_IF_SET_CONFIGURATION_REQ but no registered application on DPM. netX handles remanent data. Manual testcase evaluation shows errors.
Scenario 3)
Configuration with PNS_IF_SET_CONFIGURATION_REQ AND registered application on DPM. netX handles remanent data. Manual testcase evaluation shows errors.
Attachments
Issue Links
- discovered
-
PSPNCORE-111 Diagnosis database not thread safe
- Closed
-
PSPNSV4-449 Remanent data handling by host not possible
- Closed