Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V4.8.0.0
-
Fix Version/s: V4.8.0.9
-
Labels:None
-
Account:SPC Profinet Slave V4 operational (SPC-PSPNSV4-OPERATIONAL)
Description
Precondition:
Firmware is configured and visible via DCP on the network, has an IP address assigned and application has an active TCP socket. No cyclic Profinet communication is established.
Error trigger:
The IP address is changed via Profinet DCP protocol.
Error consequence:
The netX52 firmware crashes, SYSLED is yellow.
A powercycle is required to recover the device.
Affected firmware:
Only netX52 firmware is affected by this issue in branch V4.8.0.x.
Attachments
Issue Links
- relates to
-
PSPNSV4-1622 IP based communication no longer possible if IP is changed at runtime via DCP while Socket API configuration is active
-
- Closed
-