Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-1629

netX52 firmware crash if IP is changed at runtime via DCP while Socket API configuration is active

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.8.0.0
    • Fix Version/s: V4.8.0.9
    • Labels:
      None
    • Account:
      SPC Profinet Slave V4 operational (SPC-PSPNSV4-OPERATIONAL)

      Description

      Precondition:
      Firmware is configured and visible via DCP on the network, has an IP address assigned and application has an active TCP socket. No cyclic Profinet communication is established.

      Error trigger:
      The IP address is changed via Profinet DCP protocol.

      Error consequence:
      The netX52 firmware crashes, SYSLED is yellow.

      A powercycle is required to recover the device.

      Affected firmware:
      Only netX52 firmware is affected by this issue in branch V4.8.0.x.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: