IP based communication no longer possible if IP is changed at runtime via DCP while Socket API configuration is active

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V4.9.0.0
    • Fix Version/s: V4.9.0.2, V4.9.1.0 (trunk)
    • Labels:
      None
    • Account:
      SPC Profinet Slave V4 operational (SPC-PSPNSV4-OPERATIONAL)

      Description

      Precondition:
      Firmware is configured and visible via DCP on the network, has an IP address assigned and application has an active TCP socket. No cyclic Profinet communication is established.

      Error trigger:
      The IP address is changed via Profinet DCP protocol.

      Error consequence:
      The device is no longer reachable/visible via IP. ARP frames are not responded, SNMP is not working, Profinet RPC based services are no longer working.

      A powercycle is required to recover the device.

      Affected versions:
      PNS V4.9.0.0 and V4.9.0.1 are affected. Older branches, e.g. V4.8.0.x, are not affected.