Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-1561

Unexpected behavior when aborting an AR during Application Read/Write

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.7.0.0, V4.8.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the AR is aborted while a Read or Write service is beeing processed by the application, another RPC service might be rejected with unexpected status code 0x81814E01.

      In this situation it is expected, that the stack waits for the application to process the pending service before the next RPC service is issued towards the application.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: