Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V1.13.1.0, V1.14.0.0, V1.15.0.0
-
Fix Version/s: V1.15.0.6, V1.15.5.0, V1.16.1.0 (trunk)
-
Component/s: Device
-
Labels:None
-
Account:SPC Profinet Core (SPCPROFINET)
Description
When an AR is aborted during processing a read or write request in the application, another read or write request might be passed to application before the other service has been confirmed by the application. It is expected, that the protocol stack serializes acyclic services even when the corresponding AR has been aborted in the meantime. The stack shall not issue more than one acyclic service to the application at the same time.
Attachments
Issue Links
- blocks
-
PSPNSV4-1558 Upgrade Profinet Core to V1.15.5.0
- Closed
-
PSPNSV4-1562 Upgrade Profinet Core to V1.15.0.6
- Closed
-
PSPNSV5-690 Upgrade Profinet Core to V1.15.5.0
- Closed
-
PSPNSV5-694 Upgrade Profinet Core to V1.15.0.6
- Closed
- relates to
-
PSPNCORE-505 Reorganize to allow for RSI protocol handling
- Closed
- requested by
-
PSPNSV4-1561 Unexpected behavior when aborting an AR during Application Read/Write
- Closed
-
PSPNSV5-684 Unexpected behavior when aborting an AR during Application Read/Write
- Closed