Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2696

Under some special circumstances Phy expected configuration not applied

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case loadable firmware (NXLFW) or loadable module, the stack starts a timer to automatically configure the phy's using existing PDEV parameters if within 500 ms no stack configuration available. In this contex, if the application needs more time than 500ms after PowerOn to hand over the remanent data  to protocol stack  the phy's may have another (default) settings then expected.

      Linkable Object module (NXLOM) is not affected by this issue.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    RAamidi Redouane Aamidi
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: