Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2609

unexpected NameOfStation applied when executing ChannelInit or SystemReset while using Sycon.net database configuration

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.12.0.1, V3.12.2.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW 22-23
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Precondition: a firmware is used on a hardware with flash filesystem and firmware is configured with Sycon.net database and if firmware handles the remanent data

      If now a communication to IO Controller is established all is fine. If now a ChannelInit (or SystemReset or power cycle)  is executed on firmware the communication is interrupted (as expected) but never again re-established (which is unexpected).

      The firmware uses empty NameofStation after ChannelInit which is unexpected.