NameOfStation unexpectedly erased in case of database configuration

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.12.1.0
    • Fix Version/s: V3.12.2.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW 20-21
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the firmware is configured with a Sycon.net database and communication to IO Controller is established and now host application performs a ChannelInit while newly evaluating the configuration from database the NameOfStation is set to empty string. Thus no communication can be established any more.

      Only PreRelease V3.12.1.0 is affectd by this issue. All official Hotfixes and Released (including V3.12.0.0) are NOT affected by this issue.