Read record request fails if the requested length is greater than the max supported record size.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.7.0.0
    • Fix Version/s: V3.10.0.9, V3.11.0.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      According to profinet specification the requested record length may exceed the max supported record size. Regardless of the request length the stack shall provide a buffer with max supported record size (e.g 32KB) to hold read response. The Application shall check the request length, if it is shorter than the real record length then an error shall be returned else the real length shall be used to generate the record response.