Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2481

Stack crashes on invalid PNS_IF_STORE_REMANENT_DATA_RSP packet

    Details

    • Sprint:
      PI Sprint 2016 KW 30
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the host application generated an invalid response to Store Remanent Service indication packet where ulExt in the response packet has been set to zero, the protocol stack will crash due to an invalid memory access.
      It is expected that the stack does not crash on invalid response packets but detects the problem. In case of such an invalid response the fragmented transfer shall be aborted.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: