Flash based targets with database configuration lose the NameOfStation after power cycle

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.10.0.3
    • Fix Version/s: V3.10.0.4, V3.10.1.0, V3.11.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2016 KW 24/25
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The bugfix PSPNS-2453 introduced a new issue which does NOT exist in versions prior to V3.10.0.3

      The issue is after configuration database download with Sycon.net the device has a valid NameOfStation. If now IP address is set (regardless of temporarily or remanent) and a power cycle is done there is no NameOfStation set after the power cycle.