Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2097

wrong content in datasets to acyclically read cyclic data of a submodule in case an Owner exists (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: V3.5.52.0
    • Fix Version/s: V3.5.54.0, V3.7.0.0
    • Component/s: None
    • Labels:
      None

      Description

      The acyclic dataset RecordOutputDataObjectElement (index 0x8029) is not filled correctly in case the corresponding submodule is owned by an AR that deliveres valid IO data.
      In this case it is required to deliver either the real IO Data as "substitute data" together with IOPS "good" or to deliver other IO Data as "substitute data" together with IOPS "bad".