Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2070

several small issues in coding of dataset RecordOutputDataObjectElement (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.5.48.0
    • Fix Version/s: V3.5.52.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The dataset RecordOutputDataObjectElement that delivers the output data and the substitute data for an output submodule contains some certification relevant issues.

      • The IOPS of the SubstituteDataItem shall be "good" if SubstituteActiveFlag is set to 1
      • The SubstituteActiveFlag shall be set to 1 if no valid output IO Data exists for the submodule (e.g. AR exists but owner sends IOPS bad, no owner exists and Read Implicit or DA Read is performed)