Uploaded image for project: 'PROFINET IO-Controller V3'
  1. PROFINET IO-Controller V3
  2. PSPNMV3-519

TED conformance check failes due missing SNMP Mib entries

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.3.0.0
    • Fix Version/s: V3.3.0.5, V3.3.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      TED Check V2.35 fails when the device is connected to non Profinet neighbour devices. In that case the current MIB implementation does not deliver corresponding lldpXpnoRemEntry or lldpXdot3RemPortEntry because the related TLVs are missing in LLDP frame.

      The TED check requires the entries to be present even if the information is unkown. The corresponding MIB entries shall be added using dummy, possibly wrong values in order to make the TED check pass.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer