Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.6.0.0
    • Fix Version/s: V1.6.0.3, V1.7.0.4, V1.7.4.0, V1.8.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      If a LLDP capable but non-Profinet device is connected, the SNMP MIB does not deliver an LLDP XPno remote table entry for this device.

      According to current TED certification test, these entries shall be delivered even if the information is unknown. The implementation shall be changed to report these values using either default or dummy values.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: