Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.2.0.0, V3.3.0.0
    • Fix Version/s: V3.3.0.4, V3.3.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      The Profinet Controller firmware might send inconsistent or old process data to attached devices. While not limited to these usecases, the problem most likely occurs when the Controller is used in RT operation mode or when more process data than the firmware is able to handle within the green period is configured. For synchronized IRT usecase with small amounts of process data the issue might be not reproducible.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: