last IOPS byte for output data (biggest DPM offset) not transfered to network if DMA is used

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.7.0.900
    • Fix Version/s: V2.7.0.901
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      In case DMA is active and application handles IOPS for output data the very last byte of IOPS given by application is not transfered to the network. This issue was introduced with the fix for https://ticket.hilscher.com/browse/PSPNM-715 .

       