Uploaded image for project: 'PROFINET IO-Controller'
  1. PROFINET IO-Controller
  2. PSPNM-715

DPM Input Area overwritten by Output DMA if Provider IOPS enabled

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.7.0.900
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      When DMA Operation is enabled and the Profinet Controller Firmware is configured to use Provider IOPS, an invalid length for the DMA Transfer is calculated. As a result, the DPM Input Area might be overwritten with values from Host memory by the Output DMA Transfer. As a result invalid input process data might be passed to the host application.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: