Uploaded image for project: 'PROFINET IO-Controller'
  1. PROFINET IO-Controller
  2. PSPNM-478

sometimes no Read confirmation received in application

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.9.1
    • Fix Version/s: V2.6.9.2
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      when IO-Device deliveres more than 1556 byte for a Read record the IO-Controller stack will not send any read confirmation back to the application.

        Attachments

        1. nwid.nxd
          1 kB
        2. netx.rom
          806 kB
        3. config.nxd
          11 kB

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: