sometimes no Read confirmation received in application

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.9.1
    • Fix Version/s: V2.6.9.2
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      when IO-Device deliveres more than 1556 byte for a Read record the IO-Controller stack will not send any read confirmation back to the application.