Uploaded image for project: 'PROFINET IO-Device Interface'
  1. PROFINET IO-Device Interface
  2. PSPNDIF-58

[GCI] Handle communicating bit depending on previous state

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.0.0.1, V1.1.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When an AR has been successfully established, the communicating bit shall not be cleared until (all) AR resources have been fully released and the DPM input area will be cleared on the next DPM handshake.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: