Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V0.0.1.1
-
Fix Version/s: V1.0.0.0
-
Component/s: None
-
Labels:
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
When indicating the GCI adapter properties to the GCI application currently a hard coded magic number is given as size of remanent data.
The value does not match the data size used in HIL_STORE_REMANENT_DATA_IND. By definition of GCI the size in HIL_STORE_REMANENT_DATA_IND shall be exactly the same as used in HIL_GCI_COMP_INTERFACE_T.tInfo.ulRemanentDataSize.
If the values are not equal storing of remanent data is not working in GCI applications.
Therefore using a hard coded value at one place in source code but a calculated one at a different place in code is bad and needs to be harmonized.
Attachments
Issue Links
- clones
-
PSPNDIF-38 [GCI adapter]: wrong remanent data size indicated on GCI startup