Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V1.6.0.4 (open), V1.7.0.2, V1.7.2.0
-
Component/s: AP Task, GCI Adapter
-
Labels:None
-
Account:SPC Profinet Slave V5 operational (SPCPROFINE)
Description
The stack stores the last reported APDU status changes for each AR in a list, addressed by an AR index. However, in the case of SR-AR, the ARSet index should be used instead. The issue occurs because, when the ARSet is established, the stack incorrectly uses the wrong index to reset the last reported APDU status.
Attachments
Issue Links
- blocks
-
PSPNSV5-778 APDU Status change not reported in all cases of SR-AR scenarios
-
- Closed
-
-
PSPNSV4-1628 Upgrade Profinet Device Interface to V1.7.0.2
-
- Closed
-
-
PSPNSV5-772 Upgrade Profinet Device Interface to V1.7.0.2
-
- Closed
-
- relates to
-
PSPNSV4-1625 APDU status change not reported in all expected situations in SystemRedundancy scenarios
-
- Closed
-