Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V1.9.0.0, V1.10.0.0, V1.11.0.0, V1.12.0.0, V1.13.0.0, V1.14.0.0, V1.15.0.0, V1.16.0.0, V1.17.0.0
-
Fix Version/s: V1.14.0.16, V1.15.0.13 (open), V1.16.0.8, V1.17.0.2 (open), V1.17.1.0
-
Component/s: Controller
-
Labels:None
-
Account:SPC Profinet Core V1 operational (SPCPROFINET)
Description
When the Profinet Controller stack processes a plug submodule sequence it may abort AR the AR with status "AR RPC-Control error" when the device issues the Plug Application Ready.req. The problem occurs when in the alarm specifier one of diagnosis related bits 11 to 14 are set.
It is expected that the sequence number is correctly compared and request is accepted if the sequence number is correct.
Attachments
Issue Links
- blocks
-
PSPNMV3-976 Unexpected AR Abort during Plug or DR sequence
-
- Closed
-
-
PSPNMV3-977
Upgrade Profinet Core to V1.14.0.16
-
- Closed
-
-
PSPNMV3-978
Upgrade Profinet Core to V1.16.0.8
-
- Closed
-