Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-498

Wrong RTC3 Port states may occur during configuration changes

    Details

    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      During IRT configuration change, the switch might assume wrong RTC3 port state "RUN" or "UP". This may lead to unexpected abort of the first connection attempt with profinet status  code "DHT watchdog expired (0xCF81FD05)".

      The problem most likely shows up in SPIRTA certification test runs during Sync Slave testcases.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue