Details
-
Type: Bug
-
Status: Closed
-
Priority: Major
-
Resolution: Fixed
-
Affects Version/s: V1.6.0.0
-
Fix Version/s: V1.9.0.19, V1.11.0.11, V1.13.0.3, V1.13.1.0
-
Component/s: None
-
Labels:None
-
Account:SPC Profinet Core (SPCPROFINET)
Description
During IRT configuration change, the switch might assume wrong RTC3 port state "RUN" or "UP". This may lead to unexpected abort of the first connection attempt with profinet status code "DHT watchdog expired (0xCF81FD05)".
The problem most likely shows up in SPIRTA certification test runs during Sync Slave testcases.
Attachments
Issue Links
- blocks
-
PSPNSV4-1297 Update Profinet Core to V1.13.0.3
- Closed
-
PSPNSV4-1298 Update Profinet Core to V1.9.0.19
- Closed
-
PSPNSV5-360 Update Profinet Core to V1.13.0.3
- Closed
-
PSPNSV5-361 Update Profinet Core to V1.11.0.11
- Closed
- requested by
-
PSPNSV4-1284 Occasional AR Abort when establishing IRT connection with new configuration
- Closed
-
PSPNSV5-355 Occasional AR Abort when establishing IRT connection with new configuration
- Closed