Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V1.8.0.0
-
Fix Version/s: V1.8.0.5
-
Component/s: None
-
Labels:None
-
Account:SPC Profinet Core (SPCPROFINET)
Description
For certain Non-Profinet devices the firmware reports invalid toplogy information in SNMP and record objects:
- PDPortDataReal might contain a NameOfStation
- lldpXPnoRemPortNoS is created from PortMacAddress if Chassis Mac Address could not be determined
The returned information should behave as defined in specification. PDPortDataReal should contain a NameOfStation only for Profinet Devices (Detected by existence of Profinet Chassis Id LLDP TLV) and lldpXPnoRemPortNoS should be omitted the device is a Non-Profinet Device and the chassis mac could not be determined.
Attachments
Issue Links
- clones
-
PSPNCORE-401 Invalid topology data report for some Non-Profinet neighbour devices
- Closed
- relates to
-
PSPNSV5-259 update to PN Core V1.8.0.5
- Closed