Record object ARData may contain wrong content once IRT was used

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.8.0.0
    • Fix Version/s: V1.8.0.4
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      The record object ARData lists all currently established ARs with their properties. This object returns wrong content after the following sequence:

      1. An AR was established with IRT
      2. The AR is released and again established as RT AR (without IRT)

      After that the object contains an IRInfoBlock for the RT-AR although such an block was not sent by the controller.

      It is expected that IRInfoBlock is generated only when it was sent by the controller during connect.