Description
The record object ARData lists all currently established ARs with their properties. This object returns wrong content after the following sequence:
- An AR was established with IRT
- The AR is released and again established as RT AR (without IRT)
After that the object contains an IRInfoBlock for the RT-AR although such an block was not sent by the controller.
It is expected that IRInfoBlock is generated only when it was sent by the controller during connect.